FOR SALE: Building Plot with Utilities and Sea View
The plot has electricity, water, and optical cable connections already in place. From the highest point of the land, there is a partial view of the sea.
When directly implementing the Plan, the surface area of the building plot cannot be smaller than:
For the construction of a detached building: 400 m, with a condition that the plot width along the building line is not less than 14.0 m.
For the construction of a semi-detached building (duplex): 300 m, with a condition that the plot width along the building line is not less than 11.0 m.
For the construction of a terraced building (row): 250 m, with a condition that the plot width along the building line is not less than 8.0 m, except in dense areas of the settlement, where the width must not be less than 6.0 m.
The surface area of the building plot should generally not exceed:
No limitations for the construction of a detached building.
500 m for the construction of a semi-detached building (duplex).
300 m for the construction of a terraced building (row).
The minimum distance of the building from the boundaries of the plot is 3.0 m, measured from the most protruding parts. The distance of the main building from the road alignment of the classified road cannot be less than 6.0 m.
The minimum area of land under the building is 64 m, regardless of the size of the plot.
INDIVIDUAL RESIDENTIAL BUILDING
An individual residential building is one that contains up to three apartments.
An individual residential building can be constructed as a detached, semi-detached, or terraced building (row).
When directly implementing the Plan within the developed part of the construction area, the following location conditions for the construction of a residential building with a gross floor area of up to 450 m are determined:
Maximum permitted build-up coefficient for an individual residential building:
Detached building on a plot of 400-500 m, kig max = 0.25
Detached building on a plot of 4,500 m, kig max = 0.30, but not exceeding 450 m of gross floor area (550 m only with UPU)
Semi-detached building (duplex) kig max = 0.30
Terraced building (row) kig max = 0.30
Maximum permitted utilization coefficient for an individual residential building:
For detached buildings kis max = 0.75 with a gross floor area of up to 450 m
For semi-detached buildings kis max = 0.90 with a gross floor area of up to 450 m
For terraced buildings kis max = 0.90 with a gross floor area of up to 450 m